Qualification Testing

SLC products are designed and manufactured for compliance with the following specifications as applicable:

  • Bond Strength: MIL-STD-883, method 2001, 3 grams minimum with .001” diameter wire
  • Die Shear Strength: MIL-STD-883, method 2009. limit per standard, figure 2019-4
  • Temperature Characteristic: The capacitance change can be determined by measurement of the capacitance change at various temperatures from ambient, (25°C), within the operating temperature range. (25 +/- 2 °C to -55 +/- 2 °C, to 25+/- 2 °C to +125 +/- 2 °C)
  • Thermal Shock: MIL-STD-202F method 107 condition D
  • Immersion: MIL-STD-202F method 104 condition A
  • Moisture Resistance: MIL-STD-202, method 106, items 7a and 7b not applicable
  • Life Test: MIL-STD-202, method 108, condition D or F @ 125°C @ 2X rated voltage
  • Low Voltage Moisture: MIL-STD-49464, P 3.17, 240 hours @ 85 +/- 2°C in 85 +/- 5% RH with applied bias voltage of 1.5Vdc +/- 10%
  • Solderability: MIL-STD-202, method 208 245 +/- 5 °C, 5 seconds
  • Solder Heat Resistance: MIL-STD-202, method 210 260 °C +/- 5 °C, 5 seconds
  •